864 See Through GreenSmart™ Fireplace Report # 028-F-84-5 ANSI Z21.88a-2007/CSA 2.33a-2007 CSA P.4.1-02, CGA 2.17-M91 • Built-In Direct Vent Fir
10 Installation (for qualified installers only) © Travis Industries 4090507 100-01217_000 Converting the Fireplace to Side Vent (continued) Re-at
Installation (for qualified installers only) 11 © Travis Industries 4090507 100-01217_000 Fireplace Placement Requirements • Fireplace must be
12 Installation (for qualified installers only) © Travis Industries 4090507 100-01217_000 Minimum Framing Dimensions – Top or Side Vent Configurati
Installation (for qualified installers only) 13 © Travis Industries 4090507 100-01217_000 Nailing Brackets There are eight nailing brackets on t
14 Installation (for qualified installers only) © Travis Industries 4090507 100-01217_000 Gas Line Requirements MASSACHUSETTS INSTALLATIONS - WAR
Installation (for qualified installers only) 15 © Travis Industries 4090507 100-01217_000 Gas Line Location The gas inlet is located 1-1/4"
16 Installation (for qualified installers only) © Travis Industries 4090507 100-01217_000 Electrical Connection (required) • The electrical line t
Installation (for qualified installers only) 17 © Travis Industries 4090507 100-01217_000 Optional Wall Switch or Thermostat Installation Do no
18 Installation (for qualified installers only) © Travis Industries 4090507 100-01217_000 Vent Requirements • The gas appliance and vent system mu
Installation (for qualified installers only) 19 © Travis Industries 4090507 100-01217_000 Approved Vent • Side vent configurations use 8"
2 Introduction © Travis Industries 4090507 100-01217_000 Overview This manual details the installation requirements for the 864 See Through (ST) GS
20 Installation (for qualified installers only) © Travis Industries 4090507 100-01217_000 Approved Vent Configurations Restrictor Position • Intak
Installation (for qualified installers only) 21 © Travis Industries 4090507 100-01217_000 Intake Restrictor Adjustment The intake restrictor is
22 Installation (for qualified installers only) © Travis Industries 4090507 100-01217_000 Diffuser Plate Adjustment Certain vent configurations req
Installation (for qualified installers only) 23 © Travis Industries 4090507 100-01217_000 Side Vent Configuration with Horizontal Termination (n
24 Installation (for qualified installers only) © Travis Industries 4090507 100-01217_000 Side Vent Configuration with Horizontal Termination (with
Installation (for qualified installers only) 25 © Travis Industries 4090507 100-01217_000 Side Vent Configuration with Vertical Termination • T
26 Installation (for qualified installers only) © Travis Industries 4090507 100-01217_000 Top Vent Configuration with Horizontal Termination • The
Installation (for qualified installers only) 27 © Travis Industries 4090507 100-01217_000 Top Vent Configuration with Vertical Termination • Th
28 Installation (for qualified installers only) © Travis Industries 4090507 100-01217_000 Termination Requirements ! Venting terminals shall not
Installation (for qualified installers only) 29 © Travis Industries 4090507 100-01217_000 Hearth Requirements Do not build a hearth more than 1”
Table of Contents 3 © Travis Industries 4090507 100-01217_000 Introduction Overview ...
30 Installation (for qualified installers only) © Travis Industries 4090507 100-01217_000 Facing Requirements • This appliance is designed to allo
Installation (for qualified installers only) 31 © Travis Industries 4090507 100-01217_000 Facing Overview Upgrade faces are available for this
32 Installation (for qualified installers only) © Travis Industries 4090507 100-01217_000 Thin Facing Installation (tile, marble, or other non-comb
Installation (for qualified installers only) 33 © Travis Industries 4090507 100-01217_000 Thin Facing Installation (tile, marble, under 1"
34 Installation (for qualified installers only) © Travis Industries 4090507 100-01217_000 Thick Facing Installation (stone, brick, or other non-com
Installation (for qualified installers only) 35 © Travis Industries 4090507 100-01217_000 Thick Facing with Fireplace Xtrordinair (FPX) Arched
36 Installation (for qualified installers only) © Travis Industries 4090507 100-01217_000 Thick Facing Installation - Side View DrywallMasonry or o
Installation (for qualified installers only) 37 © Travis Industries 4090507 100-01217_000 Mantel Requirements Combustible Mantels • Use the ta
38 Finalizing the Installation (for qualified installers only) © Travis Industries 4090507 100-01217_000 Steps for Finalizing the Installation 1.
Finalizing the Installation (for qualified installers only) 39 © Travis Industries 4090507 100-01217_000 5. Install the logs (see page 42). 6.
4 Safety Precautions © Travis Industries 4090507 100-01217_000 Safety Warnings: • Failure to follow all of the requirements may result in property
40 Finalizing the Installation (for qualified installers only) © Travis Industries 4090507 100-01217_000 Glass Frame Removal and Installation Warn
Finalizing the Installation (for qualified installers only) 41 © Travis Industries 4090507 100-01217_000 Glass Frame Removal and Installation (c
42 Finalizing the Installation (for qualified installers only) © Travis Industries 4090507 100-01217_000 Log Set Installation Logs in Place – FRON
Finalizing the Installation (for qualified installers only) 43 © Travis Industries 4090507 100-01217_000 Center Log Installation The log shelf
44 Finalizing the Installation (for qualified installers only) © Travis Industries 4090507 100-01217_000 Front Left Log Place the front left log a
Finalizing the Installation (for qualified installers only) 45 © Travis Industries 4090507 100-01217_000 Front Left Upper Log There are two pin
46 Finalizing the Installation (for qualified installers only) © Travis Industries 4090507 100-01217_000 Front Upper Center Log The front upper ce
Finalizing the Installation (for qualified installers only) 47 © Travis Industries 4090507 100-01217_000 Back Left Log The back left log fits t
48 Finalizing the Installation (for qualified installers only) © Travis Industries 4090507 100-01217_000 Right Ember Chunk The right ember chunk
Finalizing the Installation (for qualified installers only) 49 © Travis Industries 4090507 100-01217_000 Back Left Log The pin on the center lo
Safety Precautions 5 © Travis Industries 4090507 100-01217_000 Safety Warnings (continued): • Allow the heater to cool before carrying out any m
50 Finalizing the Installation (for qualified installers only) © Travis Industries 4090507 100-01217_000 Back Upper Right Log Pins on the center
Finalizing the Installation (for qualified installers only) 51 © Travis Industries 4090507 100-01217_000 Ember Placement A bag of embers is pro
52 Finalizing the Installation (for qualified installers only) © Travis Industries 4090507 100-01217_000 LP Conversion Instructions Install the co
Finalizing the Installation (for qualified installers only) 53 © Travis Industries 4090507 100-01217_000 3 Follow the directions below to remov
54 Finalizing the Installation (for qualified installers only) © Travis Industries 4090507 100-01217_000 4 Remove the pilot orifice following the
Optional Equipment (for qualified installers only) 55 © Travis Industries 4090507 100-01217_000 Fireback Installation WARNING: Turn off gas to
56 Optional Equipment (for qualified installers only) © Travis Industries 4090507 100-01217_000 4 Carefully place the floor firebacks into posit
Optional Equipment (for qualified installers only) 57 © Travis Industries 4090507 100-01217_000 Grill Installation Certain faces allow for insta
58 Optional Equipment (for qualified installers only) © Travis Industries 4090507 100-01217_000 Extra Room Power Heat Duct SKU 98500769 Special Ins
Optional Equipment (for qualified installers only) 59 © Travis Industries 4090507 100-01217_000 Andiron Installation Install the andirons after
6 Features and Specifications © Travis Industries 4090507 100-01217_000 Installation Options • Residential or Mobile Home • Flush or Recessed Fac
60 Optional Equipment (for qualified installers only) © Travis Industries 4090507 100-01217_000 GreenSmart™ Remote Control Installation Packing Lis
Optional Equipment (for qualified installers only) 61 © Travis Industries 4090507 100-01217_000 Overview The GreenSmart remote installs onto a
62 Optional Equipment (for qualified installers only) © Travis Industries 4090507 100-01217_000 GreenSmart Wiring Diagram CN4CN3PILOTSENSORSPARK RO
Optional Equipment (for qualified installers only) 63 © Travis Industries 4090507 100-01217_000 Installation WARNING: Make sure power to the fi
64 Optional Equipment (for qualified installers only) © Travis Industries 4090507 100-01217_000 4 Disconnect the molex connector leading to the ga
Optional Equipment (for qualified installers only) 65 © Travis Industries 4090507 100-01217_000 7 Unscrew the on/off/battery plate from the con
66 Optional Equipment (for qualified installers only) © Travis Industries 4090507 100-01217_000 10 The stepper motor (adjustable regulator) has an
Optional Equipment (for qualified installers only) 67 © Travis Industries 4090507 100-01217_000 13 Attach the blue and white wires to the IPI/C
68 Optional Equipment (for qualified installers only) © Travis Industries 4090507 100-01217_000 16 Disconnect the power lead from accent light an
Optional Equipment (for qualified installers only) 69 © Travis Industries 4090507 100-01217_000 18 Pull the “RECEIVER” connector through the co
Installation (for qualified installers only) 7 © Travis Industries 4090507 100-01217_000 Packing List • Propane Conversion Kit • Log Set • Fir
70 Optional Equipment (for qualified installers only) © Travis Industries 4090507 100-01217_000 Figure 31 Figure 32 21 Clip any excess wiring int
Optional Equipment (for qualified installers only) 71 © Travis Industries 4090507 100-01217_000
72 Index © Travis Industries 4090507 100-01217_000 Index Additional Items Required ... 7 Andiron Installat
8 Installation (for qualified installers only) © Travis Industries 4090507 100-01217_000 Massachusetts Requirements NOTE: The following requirement
Installation (for qualified installers only) 9 © Travis Industries 4090507 100-01217_000 Top Vent or Side Vent Configuration This appliance is s
Commentaires sur ces manuels